Lianyungang Huaneng Power Auxiliary Equipment Co., Ltd. · ISO 9001:2015
Custom Rotary Film Deaerator for Boiler Systems
Custom Rotary Film Deaerator for Boiler Systems is one of our core products. From single replacement units to full power-plant retrofits, every custom rotary film deaerator for boiler systems is designed, welded, assembled and pressure-tested in our own works in Lianyungang.
- ✓ Quotation in 12 working hours
- ✓ MOQ from 1 pc
- ✓ DDP door-to-door
Custom Rotary Film Deaerator for Boiler Systems engineered and fabricated in-house
Every custom rotary film deaerator for boiler systems enquiry is reviewed by our design engineers first: duct dimensions, media temperature and dust load, sealing-air availability and actuator interface are checked against your flowsheet before we quote, so the unit you receive bolts into the existing ductwork without rework.
What we deliver
- Spray-tray or rotary-film internals engineered for stable oxygen removal across load swings
- Sponge-iron media vessels with long-life filter material and simple replacement
- Horizontal or vertical arrangement matched to the boiler house layout
- Complete skid: vessel, internals, level control, safety valve and instrumentation
- Factory acceptance test with leakage, torque and sealing-air reports for every unit
Technical specifications
| Body material | Boiler Systems (and 30+ certified grades) |
|---|---|
| Product | Rotary Film Deaerator |
| Sealing class | dissolved oxygen outlet below 0.03 mg/L (sponge-iron type) or 0.07 mg/L (spray-tray type) |
| Media | Boiler feedwater, industrial circulating water |
| Temperature | Working pressure 0.02–0.6 MPa, saturated temperature duty |
| Size range | Capacity from 2 t/h to 220 t/h per unit |
| Actuation | Electric, pneumatic, electro-hydraulic or manual |
| Standards | ISO 9001:2015, GB/DL/T design codes, third-party inspection on request |
Why buyers choose Huaneng Power Auxiliary Equipment for custom rotary film deaerator for boiler systems
We quote within 24 working hours, keep a dedicated engineer on every project and never subcontract the critical welding and machining. That is why most of our revenue comes from repeat orders and maintenance shutdown programs.
- 24-hour quotation: sizing calculation, sealing concept and actuator recommendation included.
- Leakage performance: dissolved oxygen outlet below 0.03 mg/L (sponge-iron type) or 0.07 mg/L (spray-tray type) verified by factory acceptance testing before shipment.
- Material traceability: mill certificates archived per heat number, retrievable for 5 years.
- Retrofit capability: units dimensioned from site drawings, templates or measured flange positions.
- Qualified supplier: approved by Sinopec, PetroChina, China Guodian, China Datang, CNOOC and Chalco.
Boiler systems applications
In boiler systems duty the custom rotary film deaerator for boiler systems works continuous thermal deoxygenation of feedwater. We size the shaft, bearings and actuator for the actual dust load and temperature of the duct, not just the nominal cross-section, because a gate that jams during a shutdown trip costs far more than the difference in purchase price. Critical welds are inspected 100% on the first unit and by sampling (AQL 1.0) afterwards.
How the project runs
- Send your enquiry — duct dimensions, media and temperature, or drawings of the existing installation.
- Engineering review — sizing, sealing concept, material selection and actuator proposal within 24 hours.
- Quotation — itemized fabrication, actuation, sealing-air system and packing cost.
- Drawing approval — GA and detail drawings issued for your sign-off before production starts.
- Fabrication & FAT — cutting, welding, machining and assembly, then leakage and torque testing witnessed by you or SGS/BV.
- Shipping & support — seaworthy wooden cases, export documentation, installation and commissioning guidance on site.
Related capabilities
Buyers sourcing custom rotary film deaerator for boiler systems usually also review our Rotary Film Deaerator capability, Boiler systems manufacturing solutions and request a quote. Full dimensional and material documentation is available on request.
FAQ
Questions about Custom Rotary Film Deaerator for Boiler Systems
What is the price of custom rotary film deaerator for boiler systems?
Pricing depends on size, material and sealing class. Send us the duct dimensions, design temperature and pressure, and we will return a detailed quotation with material and fabrication cost breakdown within 24 hours. Replacement units for existing installations can be dimensioned from site drawings or photos.
What is the lead time for custom rotary film deaerator for boiler systems?
Standard sizes ship in 20–30 working days after drawing approval; custom-engineered units typically need 25–35 days including internals fabrication. Worldwide export packing and shipping are available.
Can you match our existing installation?
Yes. Most of our output is retrofit work: we dimension flue gas dampers, slide gates and silencers from site drawings, templates or measured flange positions, and supply mating flanges, expansion joints and sealing-air systems to match.
Do you support boiler systems projects?
Yes. We supply boiler systems operators with custom rotary film deaerator for boiler systems units tested for leakage, actuator torque and sealing-air pressure, complete with commissioning support and spare sealing parts. Our qualifications cover Sinopec, PetroChina, China Guodian, China Datang, CNOOC and Chalco supplier systems.